Product Name: 5V6A Battery Tester Model: ACEM-CT4008-5V6A/100mA Origin: China Warranty:One Year warranty with lifetime support. Battery capacity tester 5V6A for lithium battery 18650 and polymer battery testing.
Product Description
5V6A Li-ion 8 Channel Battery Tester Battery Analysing Equipment
The 5V6A battery testing system adopts advanced testing equipment and algorithms, Through high-precision testing, the quality of batteries during the production process can be tracked and controlled, ensuring that each batteries meets strict quality standards.
Product features:
•ACEM-CT4008-5V6A/100mA Battery tester equipment is an eight-channel battery analyzer to analyze polymer battery and cylindrical batteries from 12.0 mA to 6000 mA, up to 5V
•This battery test system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc.
•CT4008-5V6A Series testing system has more quick sampling speed, attached with DC Resistance testing function. It also add with Channel parallel function which can enlarge the current up to twice of the normal range.
•If you use this tester to test Super capacitor, please choose the model ACEM-4008T-5V6A-F, with the min discharge voltage up to 0 V, Suitable for super capacitor, NI-MH battery, Nickel-chromium battery and all kind of rechargeable battery testing.
Product Parameters |
||
Project index |
Parameter index |
|
Input Power |
AC 220V ±10% / 50Hz |
|
resolution |
AD:16bit;DA:16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
425W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Voltage Range |
Charge:25mV~5V;Discharge:1.0V~5V |
Accuracy |
± 0.05% of FS |
|
Stability |
0.05% of FS |
|
Current |
Per Channel Output Current Range |
Range1:0.5mA~0.1A;Range2:0.1A~6A;Range3: 3A~6A |
Accuracy |
± 0.05% of FS |
|
CV cut-off current |
Range 1: 0.2mA Range2: 6mA; Range3: 12mA; |
|
Stability |
0.05% of FS |
|
Power |
Per Channel Output Power |
30W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time |
The Current gets to 6A Hardware Response Time is 1ms |
Step Time Range |
0.1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00(h,min,s) |
|
Data Recording |
Record Condition |
Minimum sampling time: 100ms |
Minimum sampling voltage: 10mV |
||
Minimum sampling current: Range 1: 0.2mA; Range 2: 12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging |
End Condition |
Voltage,Current,Relative Time,Capacity,-△V |
|
Discharge |
Discharge Mode |
Constant current discharge, constant power discharge, constant resistance discharge |
End Condition |
Voltage, current, relative time, capacity |
|
Pulse |
charge |
Constant current mode, constant power mode |
Discharge |
Constant current mode, constant power mode |
|
Min Pulse Width |
500ms |
|
Automated Switch |
Automated swith from charge to discharge for each pulse |
|
End Condition |
Voltage, Test Time |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
Power-down Data Protection |
Off-line Testing Function |
||
l Setting Protection Condition,Setting Parameter: Low Voltage limit,Upper Voltage limit,Low Current limit, Upper Current limit,Delay Time |
||
Hardware Protection |
Additional Anti-reverse Protection Model |
|
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<85dB |
|
IP protection level |
Protection level IP20 |
|
Channel characteristics |
The constant current source and constant voltage source adopt a dual closed-loop structure |
|
Channel control mode |
Independent control |
|
Database |
Using MySQL database to centrally manage test data |
|
Communication method of upper computer |
Based on TCP/IP protocol |
|
Server operating system |
Windows 7 |
|
Data output method |
EXCEL2003,2010、TXT |
|
Server disk configuration |
500GB |
|
communication interface |
Network interface |
|
Leakage current |
0.005mA |
|
Number of channels for the entire machine |
8 |
|
Product Dimensions |
3U1F,W480*D380*H130(mm) |
Equipment working environment requirements |
|
Indicator project |
Indicator parameters |
Working temperature range |
0℃~40℃(within the range of 25+10℃, ensure measurement accuracy: accuracy drift of 0.005% of FS/℃) |
Storage temperature range |
-10℃~50℃ |
Range of relative humidity in the working environment |
≤ 70% RH (no condensation of water vapor) |
Range of relative humidity in storage environment |
≤80% RH (no condensation of water vapor) |
Email: Katia@acemenergy.com
Mob.: +86 139 6064 6144
WeChat: +86 139 6064 6144
Skype: Katia@acemenergy.com
Whatsapp: +8613960646144
Add.: No.101, Guyan Road, Xiang'an District, Xiamen City, Fujian Province, China
Sign In